Bitta platforma, to'rt sig'im
LEIYU 21 V platformasida barcha 21 V asboblarga mos keladigan 2,0, 4,0, 6,0 va 8,0 Ah akkumulyatorlar bor. Ixcham XLY-16-10 drel maxsus 16,8 V akkumulyatordan foydalanadi.
| Sig'im | Bitta akkumulyator og'irligi | Standart to'plamdagi modellar |
|---|---|---|
| 2,0 Ah | 0,389 kg | XLY-21-10, XLY-6035, XLY-6040 |
| 4,0 Ah | 0,63 kg | XLY-600, XLY-380, XLY-21-13, XLY-01-18, XLY-205, XLY-6035, XLY-6040, LY-75C, XLY-806, XLY-807, XLY-177 |
| 6,0 Ah | 0,87 kg | XLY-1000, XLY-600, XLY-380, XLY-21-13C, XLY-26-1, XLY-26-2, XLY-05-24, XLY-100, XLY-101, XLY-150, XLY-305, LY-200, XLY-200S, LY-75C, XLY-SET-2, XLY-SET-3, XLY-SET-4-600, XLY-SET-4-1000 |
| 8,0 Ah | 0,916 kg | XLY-2000 |
Sig'imni qanday tanlash kerak
- 2,0 Ah: drellar, sekatorlar va kichik yuklamali, tanaffuslar bilan ishlaydigan boshqa asboblar uchun eng yengil variant.
- 4,0 Ah: drellar, parchinlash asboblari, metall qaychilar va 380 hamda 600 gaykovyortlar uchun universal sig'im.
- 6,0 Ah: gaykovyortlar, bolgarkalar, perforatorlar va diskli arralar uchun asosiy sig'im.
- 8,0 Ah: yuqori aylantiruvchi moment va uzoq ish uchun, XLY-2000 ning standart to'plami.
Qishda foydalanish
Markaziy Osiyoda qish sovuq bo'ladi, past haroratda litiy akkumulyatorning foydalanish mumkin bo'lgan sig'imi sezilarli kamayadi. Tavsiya qilamiz:
- Akkumulyator ishlatilmayotganda uni xonada yoki termokonteynerda saqlang. Ishdan oldin o'rnating.
- Ko'chada ishlagandan keyin zaryadlashdan oldin akkumulyatorni xona haroratigacha isitib oling.
- Qishki ishlar uchun zaxira akkumulyator tayyorlang va ularni navbatma-navbat almashtiring.
Zaryadlash va saqlash
- 0 dan 40 °C gacha haroratda shamollatiladigan xonada, oson yonuvchi materiallardan uzoqda zaryadlang.
- LEIYU 21 V zaryadlash qurilmasidan foydalaning.
- Ishlatilmayotgan akkumulyatorlarni o'z vaqtida qayta zaryadlang: zaryadni taxminan yarmida saqlang va har 2-3 oyda bir marta zaryadlang, shunda ular uzoqroq xizmat qiladi.
- Bitta bo'linma qolganda zaryadlang, uzoq muddatli chuqur razryaddan saqlaning.
Qachon foydalanishni to'xtatish kerak
Agar akkumulyator korpusi singan, deformatsiyalangan yoki shishgan bo'lsa, zaryadlash vaqtida qattiq qizisa yoki hid chiqarsa, darhol foydalanishni to'xtating. Mahalliy qoidalar bo'yicha utilizatsiyaga topshiring, qismlarga ajratmang.
Akkumulyatorga 1 yil kafolat; suv tekkan, tushib ketib shikastlangan yoki korpusi almashtirilgan akkumulyatorlar kafolatga kirmaydi.
Bu umumiy tavsiyalar. To'plamdagi yo'riqnomaga amal qiling.